KT Controller Specs, Wiring and Model Reference

KT controller specifications

KT controller specifications: 11 models quoted from manufacturer or vendor documentation. The table is the reference for voltage range, rated power and rated current; every row links to its source.

Model Type Voltage Power Current Source
KT36/48SVPRM 25A controller 36–48 V 750 W 25 A source
KT 9-tube controller (02A) controller 24–72 V 1800 (upper limit) W 25 A source
KT 40-75V 25A sine wave controller 40–75 V 750 W 25 A source
CONTROLLER-KT36-48SVPRC-36-48V-14A controller 36–48 V 250.0 W 14.0 A source
KT36-48SVPRD-36-48V-17A-BLACK-SM controller 36–48 V 450.0 W 17.0 A source
KT3648SVPRCLB-36-48V-30A-SM controller 36–48 V 1000.0 W 30.0 A source
SINUS-KT36-48SVPRCLB-36-48V-30A-MIT-KABE controller 36–48 V 1000.0 W 30.0 A source
KT36/48SVPRM controller 36–36 V 500 W 25 A source
KT3648SVPRCLB controller 36–48 V 750 W – A source
KT36/48SVPRD controller 36–48 V 350 W 17 A source
KT36/48SVPRC controller 36–48 V 250 W – A source

Voltage classes covered

24 V, 36 V, 40 V.

Documented compatibility statements

Model Relation Fits / works with Basis Source
KT36/48SVPRM fits_motor_power 500 W (36V) / 750 W (48V) rated dealer source
KT36/48SVPRM supports_display KT KT series (TX/RX) dealer source
KT36/48SVPRM has_connector SM (main) / Julet (motor) dealer source
KT36/48 series supports_display KT KT series (TX/RX) dealer source
KT36/48 series supports_display KT KT series (TX/RX) dealer source
KT36/48 series supports_display KT KT series (TX/RX) dealer source
KT36/48 series supports_display KT KT series (TX/RX) dealer source
KT36/48 series supports_display KT KT series (TX/RX) dealer source
KT36/48 series supports_display KT KT series (TX/RX) dealer source

Questions this page answers

How many KT controllers are in this dataset?

11 models.

How is the voltage range defined?

It is the minimum and maximum voltage published for that model; where a source lists only one value, the range collapses to that value.

Related

How this page was built

Rows are assembled from the component specification table, the error-code table and the compatibility relation table. Each row keeps its source link; no value is inferred from a different model.

Every value above is taken from the linked source. Fields the source does not publish are marked "not published" rather than estimated.